Rolling Upgrade
Focus
Focus
Prisma AIRS

Rolling Upgrade

Table of Contents

Rolling Upgrade

Learn the procedures for conducting a rolling upgrade on the HSF cluster.
Where Can I Use This?What Do I Need?
  • Prisma AIRS
  • Software NGFW Credits
  • HSF subscription license
To execute a rolling upgrade:
  1. Ensure that the new image OVA file has been uploaded to the content library on vCenter.
  2. Modify the firewall image within the plugin configuration, commit the changes, and then initiate an update.
  3. The plugin will download the new firewall image, which can be found under Device Deployment > Software.
  4. Upload this image to all nodes within the HSF cluster.
Image installation proceeds one node at a time, commencing with the gateway nodes. Following the successful installation of an image on a node, the node will reboot, and the plugin will await the node's return to an Online state before proceeding to the subsequent node. Should any failure occur or if an upgraded node fails to reach an Online state.
If rollback is enabledAll successfully upgraded nodes will revert to the previous image, and the update workflow will be aborted.
If rollback is disabledThe remaining nodes will not be upgraded to the newer PAN-OS image, and the update workflow will be aborted.
In the event of an upgrade failure caused by an intermittent issue, a recover operation can be utilized to reattempt a previously incomplete plugin update.