The following are common HSF topologies:
These are not the only topologies; you may choose your own sizing to get in-between throughputs.
Hardware
(Minimum)
ServersLinksP-NodeS-NodeVCPUMemoryHard disk
5 Gbps1
Total: 10 10G links
Management link + 4 links per P-Node
20
Total: 10 vCPU
5 vCPU per P-Node
Total: 32G
16G per P-Node
Total: 120G
60G per P-Node
10 Gbps1
Total: 10 10G links
Management link + 4 links per node
20 (can auto-scale)
Total: 20 vCPU
10 vCPU per P-Node
Total: 32G
16G per P-Node
Total: 120G
60G per P-Node
+Auto-scale
(5 - 10 Gbps use-case)
+1
Total links:
Management link + 2 links per S-Node
N/AUp to 64 vCPU per S-Node8G per S-Node60G per S-Node
130 Gbps
(Auto-scale up to 2 extra S-Nodes using the S-Node profiles provided)
5
Management link + 4 links per P-Node
Management link + 2 links per S-Node
24
Total: 22 vCPU (P-Nodes), 128 vCPU (S-Nodes)
11 vCPU per P-Node
32 vCPU per S-Node
Total:
256G (P-Node), 256G (S-Node)
128G per P-Node
64G per S-Node
Total: 360G
60G per P-Node
60G per S-Node
200 Gbps5
Management link + 4 links per P-Node
Management link + 2 links per S-Node
36
Total: 24 vCPU (P-Nodes), 192 (S-Nodes)
8 vCPU per P-Node
32 vCPU per S-Node
Total:
384G (P-Nodes), 384G (S-Nodes)
128G per P-Node
64G per S-Node
Total: 540G
60G per P-Node
60G per S-Node