PA-7000 Series Firewall SMC-B Requirements
Learn about the PA-7000 Series firewall SMC-B system
and hardware requirements.
The following information describes the system and hardware requirements
for the second-generation Switch Management Card (SMC-B).
If you install the Switch Management Card (SMC-B), Log Forwarding
Card (LFC), or PA-7000 100G NPC in a PA-7050 firewall, you must
install the second-generation fan trays (PA-7050-FANTRAY-L-A and PA-7050-FANTRAY-R-A).
If you install these cards in a PA-7080 firewall, you must also
install the electromagnetic interference (EMI) filter. You do not
have to install these components if the last five digits of the
firewall serial number is 10,000 or greater because the PA-7050
will have the second-generation fan trays installed and the PA-7080
will have a built-in EMI filter.
- PAN-OS 9.0 or later.
- (PA-7050 only) Install the second-generation fan tray to increase cooling capacity. The Replace a PA-7050 Fan Tray topic shows how to install a fan tray.
- (PA-7080 only) Install the PA-7080 Firewall EMI Filter to reduce electromagnetic interference.