An issue exists where Prisma Access Agent fails to trigger internal
gateway authentication and update IP-user mapping when transitioning
between networks while multiple Ethernet interfaces remain active
simultaneously. This occurs specifically when a Windows 11 laptop,
connected to LAN via Prisma Access Agent to an NGFW firewall,
reconnects the LAN cable after switching to Wi-Fi, resulting in both
network interfaces being active for several seconds during the
transition.
While Prisma Access Agent successfully reauthenticates to the Prisma
Access Agent Manager and updates IP-user mapping when switching from
LAN to Wi-Fi with a single active interface, it fails to perform the
same authentication process when reconnecting to LAN while Wi-Fi
remains connected. This causes traffic impact as the source user/IP
becomes unknown to the internal gateway due to the outdated IP-user
mapping.
Workaround: Enable the Windows 11
Prevent Wi-Fi when on Ethernet setting,
which prevents both interfaces from remaining connected
simultaneously during network transitions.
|