Review a list of known issues for Prisma SD-WAN ION Release 6.4.
- Known Issues in Prisma SD-WAN ION Device Release 6.4.3
- Known Issues in Prisma SD-WAN ION Device Release 6.4.2
- Known Issues in Prisma SD-WAN ION Device Release 6.4.1
Known Issues in Prisma SD-WAN ION Device Release 6.4.3
The following table lists the known issues in Prisma SD-WAN ION Device Release 6.4.3.
| Issue ID | Description |
|---|---|
| CGSDW-36321 | The DHCP-relay forwards the DHCP server reply to an incorrect destination. This issue occurs when the network configuration contains overlapping IP addresses across multiple VRF instances. |
| CGSDW-33589 This issue is resolved in ION version 6.3.7. | The device does not add aggregated routes learned via BGP to the FIB. This occurs when the system receives a BGP aggregate that contains connected subnets or VLANs. |
| CGSDW-35622 This issue is resolved in ION version 6.4.3 and 6.5.3. | Data traffic is leaving out of controller port of the DC ION because the controller prefix was not getting updated with the core peer IP. |
| CGSDW-30883 This issue is resolved in ION version 6.3.6. | rtr_mgr_api exception observed due to timing issue in handling wanpaths update & delete. |
| CGSDW-28329 This issue is resolved in ION version 6.1.9, 6.1.11, 6.3.5, and 6.5.1. | A timing mismatch between route withdrawal and the coalesce timer caused backup data center IONs to continue advertising branch prefixes when a VyOS peer flapped. |
Known Issues in Prisma SD-WAN ION Device Release 6.4.2
The following table lists the known issues in Prisma SD-WAN ION Device Release 6.4.2.
| Issue ID | Description |
|---|---|
| CGSDW-30788 This issue is resolved in ION version 6.4.3 and 6.5.3. | fp-rte corefile is generated in asymmetric LAN flow with specific policy. |
| CGSDW-27241 This issue is resolved in ION version 6.4.2 and 6.5.1. | After enabling logs for the flow controller, the logs are not rolling over correctly, thus using up all the space in the log directory. |
| CGSDW-24273 This issue is resolved in ION version 6.3.4 and 6.4.2. | Manually shutting down an interface fails to remove the IPv6 default route from the FIB. |
| CGSDW-22192 This issue is resolved in ION version 6.3.3, 6.3.4, and 6.4.1. | A core.fp-rte process failure occurs when client-side traffic is abruptly started and stopped. |
| CGSDW-34703 This issue is resolved in ION version 6.2.4. | A memory leak occurs when a bwm_server worker thread becomes indefinitely stuck on a recv_msg call. |
| CGSDW-32037 This issue is resolved in ION version 6.3.6. | Specific traffic patterns triggered critical memory exhaustion leading to OOM states. |
| CGSDW-27387 This issue is resolved in ION version 6.3.5. | Traffic originating from a Standard VPN was not correctly routed to branches across the fabric. |
| CGSDW-25738 This issue is resolved in ION version 6.3.4 and 6.4.2. | An issue occurred within the IPFIX socket connection logic where the socket bound exclusively to the device interface. |
Known Issues in Prisma SD-WAN ION Device Release 6.4.1
The following table lists the known issues in Prisma SD-WAN ION Device Release 6.4.1.
| Issue ID | Description |
|---|---|
| CGSDW-30069 This issue is resolved in ION version 6.3.6. | ADEM probes for private applications fail when traffic routes over the secure fabric. |
| CGSDW-31654 | FC crashes at pan_sml_vm_set_field_flag() within the ml7 library. |
| CGSDW-24973 This issue is resolved in ION version 6.4.1. | Some advertised prefixes are not displayed for a DC ION device after changing site mode. |
| CGSDW-23582 | OSPF routes are still advertised even when the WAN paths are deleted. |
| CGSDW-24482 This issue is resolved in ION version 6.2.4, 6.3.4, and 6.4.1. | An HMAC integrity failure occurred during the device upgrade process. |
| CGSDW-24112 This issue is resolved in ION version 6.3.4 and 6.4.1. | The HMAC integrity check was bypassed for several software packages during boot up. |
| CGSDW-24099 This issue is resolved in ION version 6.3.4 and 6.4.2. | Interfaces failed to program IP rules when the system scaled to 2,000 VRFs. |
| CGSDW-23397 This issue is resolved in ION version 6.3.4. | The snmp_network_discovery service restarted every hour on idle machines. |
| CGSDW-23098 This issue is resolved in ION version 6.3.4 and 6.4.1. | The system failed to detect overlapping IP subnets across different VRF instances. |
| CGSDW-22281 This issue is resolved in ION version 6.3.3, 6.3.4, and 6.4.1. | The app-probe process crashed on certain branch devices when multiple duplicate requests were received. |
| CGSDW-21868 This issue is resolved in ION version 6.3.2 and 6.4.1. | Outbound SSH6 connections failed to establish on ION devices. |
| CGSDW-21025 This issue is resolved in ION version 6.3.2. | The system failed to correctly update the performance policy cache during interface state changes. |
| CGSDW-31944 This issue is resolved in ION version 6.3.6. | The snmpd process consumed excessive memory on low-end hardware models. |
| CGSDW-27498 This issue is resolved in ION version 6.3.5 and 6.5.1. | Subinterfaces failed to retain the default route following a system reboot on PA-9200. |
| CGSDW-26226 This issue is resolved in ION version 6.1.10, 6.2.4, 6.3.4, and 6.4.2. | The DC HUB device failed to advertise /25 routes to the core in specific learning scenarios. |
| CGSDW-25586 This issue is resolved in ION version 6.1.10, 6.3.4, and 6.4.2. | The emif process crashed on ION devices when GRE was utilized with FIPS mode enabled. |