: Configure a Controller Port
Focus
Focus

Configure a Controller Port

Table of Contents

Configure a Controller Port

Let us learn to configure a controller port.
An ION device has one or two controller ports. You are allowed to configure two controller ports from
Release 5.2.1
. In a virtual interface, you can use both the controller ports to establish redundancy in controller connectivity. The controller ports can thus be in the same subnet. Controller port is by default used as source interface for controller connections and in the absence of controller port, the device automatically picks any L3 port as source interface for controller connections. If you plan to use the controller port, connect to existing LAN segment with Internet reachability.
  1. Select the controller port.
  2. To enable the interface, for
    Admin Up
    , select
    Yes
    .
  3. (Optional)
    Enter a description.
  4. For
    IPv4 Configuration
    , select
    DHCP
    or
    Static
    .
    Choose DHCP if the IP address is dynamically assigned.
    Choose Static if the IP address is fixed and is manually assigned. Additionally specify the
    IP Address/Mask
    ,
    Default Gateway
    , and
    DNS server(s)
    .
  5. Click
    Save Port
    .
    Similar to configuring the first controller port, configure the second controller port.

Add a Used-for-Controller Interface

Gen-1 ION devices, including the ION 2000, 3000, 7000, and 9000, feature a dedicated controller port designed to offer MRL connectivity, HA heartbeat exchange, and other management functions. With the release of Gen-2 ION devices, beginning with version 6.3.1, any Layer 3 interface can now be configured as a controller port, leveraging the innovative
Used-for-Controller
setting. This setting empowers the interface to furnish the same functionality seamlessly.
Prisma SD-WAN
supports
Used-for-controller
on:
  • Main Interfaces
  • Virtual Interfaces
  1. Select
    Workflows
    Devices
    Claimed Devices
    , select the device you want to configure.
  2. Select the
    Interfaces
    tab.
  3. Select a port.
  4. For
    Admin Up
    , select
    Yes
    .
  5. (Optional)
    Enter a
    Description
    .
  6. For
    Interface Type
    , select
    Port
    .
  7. For
    Use this Port for
    , select
    Controller
    .
  8. Click
    Save Port
    .