Prisma SD-WAN
Addressed Issues in Prisma SD-WAN ION Release 6.2
Table of Contents
Expand All
|
Collapse All
Prisma SD-WAN Docs
-
-
-
- CloudBlade Integrations
- CloudBlades Integration with Prisma Access
-
-
-
-
- 6.5
- 6.4
- 6.3
- 6.2
- 6.1
- 5.6
- New Features Guide
- On-Premises Controller
- Prisma SD-WAN CloudBlades
- Prisma Access CloudBlade Cloud Managed
- Prisma Access CloudBlade Panorama Managed
Addressed Issues in Prisma SD-WAN ION Release 6.2
Learn about the issues addressed in Prisma SD-WAN ION release
6.2.x.
Where Can I Use This? | What Do I Need? |
---|---|
|
|
Learn more about the issues addressed in Prisma SD-WAN ION
device release 6.2.
- Addressed Issues in Prisma SD-WAN ION Device Release 6.2.3
- Addressed Issues in ION Device Release 6.2.2
- Addressed Issues in Prisma SD-WAN ION Device Release 6.2.1
To view the consolidated list of addressed issues across Prisma SD-WAN ION releases, see
here.
Addressed Issues in Prisma SD-WAN ION Device Release 6.2.3
The following table lists the issues addressed in Prisma SD-WAN ION Device Release 6.2.3.
Issue ID | Description |
---|---|
CGSDW-3841 | Resolved an issue where a DC ION device was not advertising BGP prefixes learnt from the branch LAN peer to the core peer after an HA switchover. |
CGSDW-8622 | Resolved an issue in which the rtr-manager process was constantly restarting. |
CGSDW-13161 | Resolved an issue where the software bypass was not working after an FC restart for the ION 3200 device. |
CGSDW-13397 | Resolved an issue where the FC was crashing during a TCP SYN scan. |
CGSDW-13805 | Resolved an issue wherein received BGP routes were getting filtered in case of uneven route lengths. |
CGSDW-14164 | SNMP support extended for ION-1200-C-5G-EXP. |
CGSDW-14342 | Resolved an issue where branch to branch VPNs could not be created for the ION 1200-S device. |
CGSDW-14509 | Resolved an issue where the interface MAC address configuration was out of sync if the address was configured when the interface was down. |
CGSDW-14698 | Provided the ability to shut down PoE operations when the device CPU temperature rose above 85 degrees C. |
CGSDW-14980 | Resolved an issue where custom applications with L3/L4 prefixes were not detected when used in security policies. |
CGSDW-15039 | Resolved an issue where the domain names were not displayed for Applications on the Flows tab. |
CGSDW-15155 | Resolved an issue where the traffic would take more than 20 seconds to resume after rebooting the active ION device in an HA deployment. |
CGSDW-15201 | Resolved an issue where the ingress capacity bandwidth calculation was displaying as zero for some WAN links. |
CGSDW-15258 | Resolved an issue where the device went offline intermittently due to restart of the FC process. |
CGSDW-15393 | Addressed an issue where the Advertised auto-negotiation mode duplex setting was erroneously set to Yes following a reboot of the ION device through the web interface. |
CGSDW-15397 | Resolved an issue where explicit rule ordering was not taking precedence over implicit rule ordering for User ID based policies. |
CGSDW-15529 | Resolved an issue where the per BGP peer statistics table did not have any data. |
CGSDW-15650 | Resolved an issue where the software version 6.2.x was not compatible with ADEM for the ION 2000 device. |
CGSDW-15661 | Resolved an issue where memory leak was observed in the VPN process. |
CGSDW-15663 | Resolved an issue where the thmgr process did not start after upgrading the device software version. |
CGSDW-15828 | Resolved an issue where the alarm for Power Supply Unit (PSU) removal was not working for the ION 5200 and 9200 devices. |
CGSDW-15868 | Resolved an issue wherein high memory consumption by the ADEM process was causing other processes to crash and device to reboot. |
CGSDW-15969 | Resolved an issue where the subinterface was operational in spite of shutting down the remote parent interface on the 1200-S/3200/5200/9200 platforms. |
CGSDW-16246 | Resolved an issue where (SACK) block truncated warnings were seen in the log messages. |
CGSDW-16269 | Resolved an issue where high payload traffic sent over Private WAN VPN with a high throughput was dropping. |
CGSDW-16280 | Resolved an issue wherein the DC ION device did not forward traffic to the mgmt-vlan prefix if the management port of the core switch went down. |
CGSDW-16391 | Resolved an issue where the FC monitor was crashing after upgrading from the device from software version 5.6.13 to 6.1.3-b1. |
CGSDW-16647 | Optimized traffic loss that occurred during reboot of the device with hardware bypass pairs. |
CGSDW-16681 | Resolved an issue where the emif process was crashing on VFF. |
CGSDW-16717 | Resolved an issue where the fp-rte process was crashing if the packet size was larger than 16384. |
CGSDW-16836 | Resolved a memory leak caused by the stpstat process. |
CGSDW-16947 | Resolved an issue where fp-rte core files were being generated for traffic from a number of applications with WAN impairments. |
CGSDW-16971 | Resolved an issue of delay in VPN tunnel establishment when using same IP addresses for bypass pairs in branch HA. |
CGSDW-17094 | Resolved an issue of traffic dropping on an ION 2000 device during the switchover back to the active device in an HA setup. |
CGSDW-17214 | Resolved an issue where setting a custom value for fib_admin_distance displayed an error on the DC ION device. |
CGSDW-17284 | Resolved an issue where the FC was crashing due to ADEM. |
CGSDW-17361 | Implemented a change to handle BGP attributes. |
CGSDW-17418 | Resolved an issue where the ION 5200 and 9200 devices were unable to handle oversize packets. |
CGSDW-17461 | Resolved an issue with the programming of the VLAN on the trunk port that carries the HA control traffic. |
CGSDW-17641 | Resolved an issue where the interface did not display the IPv6 DNS Server details although the interface was enabled to receive autoconf information. |
CGSDW-17652 | Resolved an issue where the LAN to LAN traffic was not flowing. |
Addressed Issues in ION Device Release 6.2.2
The following table lists the issues addressed in Prisma SD-WAN ION Device Release 6.2.2.
Issue ID | Description |
---|---|
CGSDW-9643 | Resolved an issue where the branch ION device was going offline or was being disconnected from the controller intermittently whenever IPv6 addresses were present in the DNS responses for ION device internal services. |
CGSDW-12663 | Resolved an issue in which the HA switchover took place only after restarting the flow controller (FC). |
CGSDW-12977 | Resolved an issue that was causing a missing ARP entry for the controller gateway on reload/upgrade to version 5.6.11. |
CGSDW-13238 | Resolved an issue where the inspect flow internal command was not working. |
CGSDW-13297 | Resolved an issue where the DHCPv4 server did not start on an interface, if the interface was configured as a relay agent earlier. |
CGSDW-13415 | Resolved an issue where the CPU utilization value on the front panel of the device differed from the value on the web interface. |
CGSDW-13486 | Resolved an issue where the SNMP agent failed to start after upgrading the ION device. |
CGSDW-13720 | Resolved an issue where the IPv4 details for an interface obtained via DHCP changed, when Autoconf was used for IPv6 configuration of the interface. |
CGSDW-13819 | Resolved an issue of fc-monitor crash wherein the time taken by fc-control thread to report to fc-monitor thread was being incorrectly evaluated. |
CGSDW-14009 | Resolved an issue where the HA LED did not light up. |
CGSDW-14120 | Resolved an issue where the Flow Controller kept on restarting. |
CGSDW-14208 | Resolved an issue where the data center ION device was forwarding traffic incorrectly. |
CGSDW-14344 | Resolved an issue where the FC process was crashing when traffic was flowing through the ION device. |
CGSDW-14737 | Resolved an issue where the Local AS # was not getting updated correctly in the BGP configuration. |
CGSDW-15028 | Resolved an issue where the Radius attribute Service-Type needed to be set to Callcheck for successful MAC authentication. |
Addressed Issues in Prisma SD-WAN ION Device Release 6.2.1
The following table lists the issues addressed in Prisma SD-WAN ION Device Release 6.2.1.
Issue ID | Description |
---|---|
CGSDW-3861 | Resolved an issue wherein API calls to a branch ION device were returning inconsistent values when the vpn_to_vpn_forwarding value was set to true. |
CGSDW-7838 | Resolved an issue where the navigation through stack policies on the web interface was slow. |
CGSDW-8227 | Resolved an issue that caused the system routes to disappear during a switchover in a branch high availability (HA) deployment. |
CGSDW-10905 | Resolved an issue where a standard VPN tunnel may flap during the IKE rekey process. |
CGSDW-11059 | Resolved an issue where the API call for a device bulk configuration query for a greenfield tenant would return an invalid Tenant API version error. |
CGSDW-11150 | Resolved an issue where there could be a possibility of malicious command injections through the ION device CLI. |
CGSDW-11326 | Resolved an issue where the vION device interfaces did not display after upgrading the device from device version 5.6.5 to 6.0.1-b70. |
CGSDW-11353 | Resolved an issue wherein the Zoom Meeting application traffic destined for 206.247.0.0/16 was not identified correctly. |
CGSDW-11384 | Resolved an issue where static route polling was failing after 18 hours. |
CGSDW-11416 | Resolved an issue where application override could not be configured for some of the system applications. |
CGSDW-11976 | Resolved an issue in which the CPU utilization was reported incorrectly by the ION device. |
CGSDW-11997 | Resolved an issue where UDP sessions were timing out causing packet drops. |
CGSDW-12127 | Resolved an issue that was causing intermittent packet drops for ICMP/PING flows in WAN to LAN traffic from Prisma Access mobile users to a Prisma SD-WAN remote branch LAN host. |
CGSDW-12185 | Resolved an issue where packets were being dropped at the branch site when the TCP ports numbers were re-used between subsequent flows. |
CGSDW-12189 | Resolved an issue where the DHCP server could not configure the bootfile for devices without a PXEClient VCI. |
CGSDW-12562 | Resolved an issue where ARP packets were not being received over the virtual VLAN interface for a branch ION device. |
CGSDW-12616 | Resolved an issue where custom roles could not perform edit actions. |
CGSDW-12960 | Resolved an issue where Prisma SD-WAN tunnel would not form when using a Virtual Interface on a Data Center ION device. |