: Configure a PoE Port
Focus
Focus
Table of Contents

Configure a PoE Port

Power-over-Ethernet (PoE) is a technology that sends electrical power over twisted-pair ethernet cable to powered devices. In Prisma SD-WAN, you can configure at Interface and System level PoEs.
Power-over-Ethernet (PoE) is a technology that sends electrical power over twisted-pair ethernet cable to powered devices (PD), such as wireless access points, IP phones or cameras along with the data traffic on the same cable.
PoE ports support a maximum system PoE power of 90W that is dynamically distributed on the four PoE ports—port 7, 8, 9, 10—on a first-come-first-serve basis. Each PoE ports support up to 60W 802.3bt PoE power (4-Pair or 2-channel PoE).
The following new platforms support 4x1Gbps RJ45 PoE capable ports, with maximum of power per port of 60W, maximum power per system of 90W, and supported classes of 0-6:
  • ION 1200-S
  • ION 1200-S-C-NA
  • ION 1200-S-C-ROW
  • ION 1200-S-C5G-WW
  • ION 3200
You can configure PoE at:

Configure Interface level PoE Ports

Enable or disable PoE and the usage threshold on a port at the interface level. PoE is disabled by default.
  1. Select
    Workflows
    Devices
    Claimed Devices
    , select the device you want to configure.
  2. Select
    Interface
    tab of the device you want to configure.
  3. Select
    Configure the device
    .
  4. Select the port to enable PoE.
    Only ports 7, 8, 9, 10 are PoE capable and can be enabled.
  5. Enable PoE
    .
  6. Set
    Port Power Usage Alarm Threshold
    value between 50 - 100%.
    The default threshold is 100% (60W). If the usage threshold exceeds the configured value for the port, an alarm is generated.

Configure System Level PoE Ports

Set the system-level power usage threshold for the PoE ports.
  1. Select
    Workflows
    Devices
    Claimed Devices
    .
  2. Select the device to configure and then select
    System
    tab to set the power usage threshold for the PoE ports.
  3. On the PoE table, edit the
    Main Power Usage Threshold
    value between 50-100%
    The default value is 100%. If the usage threshold exceeds the configured value for the entire system, an alarm is generated.
  4. Save
    your changes.

Monitor PoE Activity and Stats

Monitor the activity and statistics of the PoE ports by selecting the Activity icon and the Stats icon on the System Tab.
  1. Select
    Workflows
    Devices
    Claimed Devices
    Configure the Device
    System
    PoE
    to view the PoE ports statistics and status.
  2. Select
    View Activity
    to view the PoE ports activity.
    The dashboard displays reports on PoE Power Consumption and Interface PoE Stats.