Issue ID
Description
PAN-298241
Fixed an issue where the NAT IP address pool was exhausted, which led to intermittent connectivity issues with call applications and outbound call failures. This occurred due to the firewall not properly releasing NAT dynamic ports back to the address pool.
PAN-296490
(FIPS CC mode enabled only) Fixed an issue where Panorama on GCP rebooted every hour after upgrading to 11.1.6-h10.
PAN-289249
Fixed an issue where a memory leak occurred on the reportd process when a WildFire update was initiated while device telemetry data collection was in progress. This resulted in an OOM condition.
PAN-286576
Fixed an issue where the all_pktproc process restarted, which caused heartbeat failures to occur and a slot to go down due to path monitor failure.
PAN-272245
Fixed an issue where the dnsproxy process crashed due to memory corruption caused by a race condition when the allow list downloading was impacted by config change.
PAN-267450
Fixed an issue where the reportd process stopped responding with a SIGSEGV at schedule_report_es_response.