PAN-273730
(PA-7000 Series firewalls only) Fixed an issue where the web interface became unresponsive after upgrading to PAN-OS 10.2.7-h8.
PAN-268727
Fixed an issue where traffic was dropped when the accumulation proxy was enabled and header insertion modified packets.
PAN-260131
Fixed an issue where the firewall consumed a large amount of memory when forwarding raw logs.
PAN-248752
(PA-3200 Series, PA-5200 Series, and PA-850 firewalls only) Fixed an issue where the firewall did not have enough Linux memory on the dataplane, which caused the firewall to restart.
PAN-246772
Fixed an issue on the firewall where the dataplane went down due to a path monitor failure caused by an out-of-memory (OOM) condition related to the pan_task process.