Issue ID
Description
PAN-326705
Fixed an issue where high CPU utilization occurred on one of the CPU cores.
PAN-325002
(Google Cloud NGFW Enterprise VM-Series firewalls only) Fixed an issue where the HTTP2 threat logs did not include VPC ID, Security_key, and Endpoint ID.
PAN-323485
Fixed an issue where multicast radio RTP based traffic was dropped after an upgrade when the firewall performed Cloud Inline inspection, which led to an exceeded session queue for Cloud Threat Detection.
PAN-318106
Fixed an issue where SCM did not update device telemetry for the firewall after upgrading to an affected release.
PAN-317068
Fixed an issue on the Panorama web interface where you were able to enable IPv6 for IKE gateways and IPSec tunnels even when IPv6 WAN was disabled, which resulted in an invalid configuration. To utilize this fix, upgrade to the latest Panorama plugin.
PAN-314624
Fixed an issue where the useridd process became unresponsive and restarted when attempting to dump the Host Information Profile (HIP) database via CLI while the system was actively processing HIP reports. This was caused by a lock contention. With this fix, the process now operates as expected under these conditions.
PAN-313827
Fixed an issue where a memory leak occurred related to the reportd process when custom reports were run via API.
PAN-304840
Fixed an issue where multiple firewalls experienced high management CPU utilization after upgrading to an affected release due to repeated index regeneration occurring every 15 minutes, which caused periodic CPU spikes above 90%.
PAN-303156
Fixed an issue where the session timer for a custom application did not transition from the initial 3-way handshake timer to the application timeout when out-of-order 3-way handshake packets were detected.
PAN-298788
Fixed an issue where the /pancfg partition on the Azure Cloud NGFW reached 100% utilization, which caused commit failures.
PAN-293707
Fixed an issue where the iotd process failed to install DPI Cloud server FQDN due to a configuration parsing failure, caused by the configuration XML memory buffer not being NULL terminated. This resulted in the accumulation of EAL logs and DLP forwarding being stopped.
PAN-266843
Fixed an issue on airgapped firewalls where cloud connection errors flooded the system logs.