| Where Can I Use This? | What Do I Need? |
- NGFW (Managed by Panorama)
|
- M-series hardware appliance
- Log Collector License
|
If you want a dedicated appliance for log collection, configure an M-200, M-300, M-600, or M-700
appliance in Log Collector mode. To do this, you first perform the initial
configuration of the appliance in Panorama mode, which includes licensing,
installing software and content updates, and configuring the management (MGT)
interface. You then switch the M-Series appliance to Log Collector mode and complete
the Log Collector configuration. Additionally, if you want to use dedicated
M-Series Appliance
Interfaces (
recommended) instead of the MGT interface for log
collection and Collector Group communication, you must first configure the
interfaces for the Panorama management server, then configure them for the Log
Collector, and then perform a Panorama commit followed by a Collector Group
commit.
Perform
the following steps to set up a new M-Series appliance as a Log
Collector or to convert an existing M-Series appliance that was
previously deployed as a Panorama management server.
If
you are configuring an M-Series appliance in Log Collector mode
with 10GB interfaces, you must complete this entire configuration
procedure for the 10GB interfaces to display as Up.
Switching the M-Series appliance from Panorama
mode to Log Collector mode reboots the appliance, deletes the local
Log Collector, deletes any existing log data, and deletes all configurations
except the management access settings. Switching the mode does not
delete licenses, software updates, or content updates.