: Addressed Issues in Prisma SD-WAN ION Device Release 6.0.1
Focus
Focus

Addressed Issues in Prisma SD-WAN ION Device Release 6.0.1

Table of Contents

Addressed Issues in Prisma SD-WAN ION Device Release 6.0.1

Learn about the issues addressed in Prisma SD-WAN ION device release 6.0.1.
The following table lists the issues addressed in Prisma SD-WAN ION Device Release 6.0.1.
Issue ID
Description
CGSDW-488
Resolved an issue encountered during scheduling of device software upgrade or downgrade, in which the time would not be updated if entered manually in the text box.
CGSDW-843
Resolved an issue where the System tab under Activity did not display the dropped packets for an interface.
CGSDW-1202
Resolved an issue where the endpoints were not reflecting the new name of a data center site.
CGSDW-1340
Resolved an issue wherein the physical status for a private WAN circuit for a data center site would incorrectly display
Init
.
CGSDW-3124
Resolved an issue where devices that were scheduled for future upgrade were not listed in the scheduled upgrades on the web interface.
CGSDW-3339
Resolved an issue wherein the Prisma SD-WAN fabric was unable to recover from overlapping IP addresses between two branch sites.
CGSDW-3468
Resolved an issue with orignal security policy to stacked security policy conversion when an empty prefix list was attached to the rule.
CGSDW-4432
Resolved an issue where a user was not able to create a user with a space in the first name.
CGSDW-4523
Resolved an issue where the bypass pair of a backup ION 2000 device in an HA configuration was displaying a down status but was still passing traffic.
CGSDW-4870
Resolved an issue where the BGP routes were not parsing properly due to repeated spaces between advertised AS numbers.
CGSDW-4913
Resolved an issue where VPN was not available in the list of WAN overlays when binding a security zone to a device interface for stacked security policies.
CGSDW-5057
Resolved an issue wherein DPDK was causing a high fan noise in the ION 9000.
CGSDW-5102
Resolved an issue where the data center ION device did not advertise the branch site prefix even after resolving the conflict due to overlapping branch site prefixes.
CGSDW-5262
Resolved an issue where the VPN interface string names were displayed in the output for an SNMP agent.
CGSDW-5505
Resolved an issue wherein the selected tab on the
Site Summary
page was not preserved when the time range was changed.
CGSDW-6131
Resolved an issue where the device was advertising prefixes of an earlier site even after being unassigned from the site and assigned to a new site.
CGSDW-6138
Resolved an issue where the backup device in an HA pair does not suppress alarms related to internet reachability.
CGSDW-6194
Resolved an issue where an L7 application was not being detected correctly.
CGSDW-6724
Resolved an issue where the DHCP relay did not work if both the DHCP relay and DHCP server were running on the same ION device interface.
CGSDW-9379
Resolved an issue wherein remote login to the ION device for CLI access was failing.
CGSDW-10086
Resolved an issue where the
Rtr-mgr
would leak memory and eventually run out of memory.
CGSDW-10500
Resolved an issue wherein flows were being created in certain cases for branch VPNs that had gone down.
CGSDW-10540
Resolved an issue where the Flow Controller could crash when a custom application was configured with overlapping port numbers.

Recommended For You