Issue ID Description
CGSDW-7806
This issue is now resolved in ION device software version 6.1.9. See Addressed Issues in Prisma SD-WAN ION Device Release 6.1.9.
The DHCP Relay chooses the secondary IP address instead of the primary IP address for sending a DHCP request.
CGSDW-16922The fp-rte process crashes after a software upgrade to ION device version 6.1.5-b7.
CGSDW-18905First flow of direct VNC traffic gets denied as the server port in the ION app-def is 0-0.
CGSDW-19357When a DC ION receives routes for a /32 prefix from both the underlay and overlay, the DC ION tries to split the route and thus the BGP route selection process fails.