Home
EN
Location
Documentation Home
Palo Alto Networks
Support
Live Community
Knowledge Base
>
Clear
Known Issues in Prisma SD-WAN ION Device Release 6.1.6
Updated on
Nov 28, 2024
Focus
Download PDF
Updated on
Nov 28, 2024
Focus
Home
Prisma
Prisma SD-WAN
Prisma SD-WAN ION Device Release 6.1
Known Issues in Prisma SD-WAN ION Release 6.1
Known Issues in Prisma SD-WAN ION Device Release 6.1.6
Download PDF
Known Issues in Prisma SD-WAN ION Device Release 6.1.6
Table of Contents
Filter
Expand All
|
Collapse All
Prisma SD-WAN Docs
Administration
Deployment
Incidents & Alerts
CloudBlades
Version
AWS Transit Gateway
Azure vWAN
Azure vWAN with vION
ChatBot for MS Teams
ChatBot for Slack
CloudBlades Integration with Prisma Access
GCP NCC
Service Now
Zoom QSS
Zscaler Internet Access
Reference
Release Notes
Version
ION 5.2
ION 5.3
ION 5.4
ION 5.5
ION 5.6
ION 6.0
ION 6.1
ION 6.2
ION 6.3
ION 6.4
New Features Guide
On-Premises Controller
Prisma Access CloudBlade Cloud Managed
Prisma Access CloudBlade Panorama Managed
Prisma SD-WAN CloudBlades
Previous
Known Issues in Prisma SD-WAN ION Device Release 6.1.7
Next
Known Issues in Prisma SD-WAN ION Device Release 6.1.5
Known Issues in
Prisma SD-WAN
ION Device Release 6.1.6
Learn about the known issues in
Prisma SD-WAN
ION Release 6.1.6.
The following list includes outstanding known issues specific to Prisma SD-WAN ION release 6.1.6.
Issue ID
Description
CGSDW-7806
This issue is now resolved in ION device software version 6.1.9. See
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.9
.
The DHCP Relay chooses the secondary IP address instead of the primary IP address for sending a DHCP request.
CGSDW-15027
Incorrect SNMP interface bandwidth reported after a software upgrade from ION device version 5.6.
CGSDW-15967
High memory consumption by the ADEM process causes ION device reboot.
CGSDW-16922
The
fp-rte
process crashes after a software upgrade to ION device version 6.1.5-b7.
CGSDW-18905
First flow of direct VNC traffic gets denied as the server port in the ION app-def is 0-0.
CGSDW-19237
This issue is now resolved in ION device software version 6.1.7. See
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.7
.
FC crashes due to stack corruption in ION 5200.
CGSDW-19357
When a DC ION receives routes for a /32 prefix from both the underlay and overlay, the DC ION tries to split the route and thus the BGP route selection process fails.
CGSDW-19707
This issue is now resolved in ION device software version 6.1.7. See
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.7
.
The Standard VPN path is not displayed in the list of paths when configured through easy onboarding.
Previous
Known Issues in Prisma SD-WAN ION Device Release 6.1.7
Next
Known Issues in Prisma SD-WAN ION Device Release 6.1.5