Upgrade or Downgrade Considerations in Prisma SD-WAN ION Device Release
6.3.1
Expand all | Collapse all
Upgrade or Downgrade Considerations in Prisma SD-WAN ION Device Release
6.3.1
Learn about the device upgrade or downgrade considerations for Release 6.3.1.
The following table lists the new features that have upgrade or downgrade impact.
Make sure you understand all upgrade/downgrade considerations before you upgrade to or
downgrade from Prisma SD-WAN release 6.3.1.
Feature | Upgrade Considerations | Downgrade Considerations |
Performance Policy | When upgrading to device version 6.3.1 or higher, if a performance policy is not
attached to a site, default thresholds for LQM will be applied for path
selection of both real time applications. After upgrading to 6.3.1 or
higher you cannot create / update LQM and App performance thresholds
from the advanced menu but, they can be deleted. Any configured advanced
menu values will be ignored by the device after the upgrade to 6.3.1 or
higher. | None |
IPv6 BGP Support
| None | Remove the IPv6 configuration before downgrading the
device software version. |
Support for FIPS mode
| FIPS mode will not be supported on an upgrade to
device software version 6.3.1. Device software version 6.3.4 will
support FIPS. | |