Alert and Alarm Attributes
Each event contains a bunch of attributes
that can be used to gain more information on the condition. Depending
on the type of event, the attributes that constitute the event differ.
An alarm typically consists of the following attributes:
{ "_created_on_utc": "2021-07-15T05:48:39.121000Z", "_etag": 1, "_updated_on_utc": "2021-07-15T05:48:39.121000Z", "acknowledged": false, "acknowledgement_info": null, "cleared": false, "code": "SITE_CONNECTIVITY_DEGRADED", "correlation_id": "6Qeqj3iD", "element_id": null, "entity_ref": "tenants/1092/sites/16015589439620037", "id": "60efcc376534671b7600e09f", "info": null, "notes": null, "policy_info": { "policy_applied_time": "2021-07-15T05:48:39.121000Z", "policyrule_id": null, "policyset_id": "16226851857240070" }, "priority": "p3", "severity": "major", "site_id": "16015589439620037", "suppressed": false, "suppressed_info": { "event_ids": null, "other_reasons": null, "summary_event_ids": null, "suppressed_time": null }, "time": "2021-07-15T05:10:00.098000Z", "type": "alarm" }
ID
A unique ID used to identify an event.
Code
An event code which describes the event.
Correlation ID*
Correlation ID is a system-generated ID for a raised alarm. An
Alarm is associated with two states – raise and clear.
At any given time, there can be multiple alarms with the same event
code in either a raised or cleared state. Using the Correlation
ID, you may distinguish among alarms with the same event code.
When an alarm is cleared, the Correlation ID will indicate that
the specific alarm is cleared. This ID will continue to be associated
with an alarm, even if the alarm is cleared or resolved.
Time
The time at which this condition was seen or the event was raised
or cleared.
Element ID
ID of the device on which this condition was seen.
Site ID
If the device is associated with a site, site_id will
also be packaged in the event. If not, this attribute is not present.
Type
This field indicates the event type i.e. alert or alarm.
Severity
Severity for alarms are based on the following categories:
- Critical - Whole or part of a network is down, and requires immediate action.
- Major - Network is impacted, and needs immediate attention.
- Minor - Network is degraded, and needs attention soon.
Entity Reference
Entity reference refers to the specific entity where the alarming
condition is seen. This string can be used as an API URI to query
the entity using the Prisma SD-WAN SDK. In the example above, the entity_ref attribute
contains information about the element that is disconnected from
the controller.
Info
Info sheds more lights on the entity that is causing the alarming
condition. It can contain information regarding interfaces, or IP
addresses if there is a collision. The value in this field changes
depending on the event code.
Notes
The Notes field is used to add remarks or comments to events.
You can edit notes for active alarms only.
Priority
This attribute indicates the priority of the event or alarm.
Suppressed
Suppressed is a boolean attribute that indicates if the event
is suppressed by the Prisma SD-WAN Event Correlation & Suppression
engine.
Suppressed Info
If the event is suppressed, suppressed_info contains details
about the suppression time and correlated event IDs.
Policy Info
If the event was updated using an event policy rule, the policy_info
attribute contains details about the event policy set, event policy
rule, and rule application time.
Clear*
This attribute is Boolean and indicates if the event condition
still exists or is cleared. A value of True indicates that the condition
no longer exists. When an alarm is raised, it is raised with Clear
set to False.
Acknowledged*
This attribute is Boolean and indicates if an event has been
acknowledged by a user. If acknowledged, the acknowledgement_info field
contains the time and the user who acknowledged the event.
(*) indicates it is not part of the Prisma SD-WAN alert.
A Prisma SD-WAN alert contains most of these attributes except
cleared, acknowledged and correlation_id - as alerts are not standing
conditions. Here’s a sample alert:
{ "info": { "name": "internet 1", "circuit_labels": "Budapest-INET-VZ" }, "code": "DEVICEHW_INTERFACE_ERRORS", "severity": "major", "_updated_on_utc": "2019-12-23T14:04:34.736000Z", "site_id": "15282991838450011", "id": "5e00c972d7b0fa2f8cb418ce", "entity_ref": "tenants/1083/sites/15282991838450011/elements/15230097588400085/interfaces/15230098062640233", "correlation_id": null, "time": "2019-12-23T14:04:31.395000Z", "element_id": "15230097588400085", "_created_on_utc": "2019-12-23T14:04:34.736000Z", "type": "alert", "_etag": 1 }