The following list includes all known issues that impact an SD-WAN 3.4 release. This list includes both outstanding issues and issues that are addressed, as well as known issues that apply more generally or that are not identified by a specific issue ID. Refer to PAN-OS Release Notes for additional known issues affecting SD-WAN Plugin 3.4.

PAN-300334

Description of PAN-300334.
The ADEM plugin is incompatible with PAN-OS version 12.1.2, which means that upgrading to PAN-OS 12.1.2 will prevent installation of the plugin and disable the ability to monitor remote sites on next-generation firewalls using ADEM functionality.

PLUG-19986

Description of PLUG-19986.
The SD-WAN plugin requires unique interface numbers across different interface types. The commit all operation on managed firewalls fails if you mix the interface types (such as, Ethernet, Cellular) with the same interface number. For example, the configuration push or commit all operation fails if your SD-WAN configuration contains Ethernet and Cellular interface types with the same interface numbers, like ethernet1/1 and cellular1/1.
Workaround: Ensure that you don't use the same interface number for different interfaces for your firewalls. Always verify interface numbering when configuring SD-WAN interfaces to prevent deployment issues.
This issue is addressed in SD-WAN plugin 3.3.3-h1 and 3.4.0.

PLUG-19495

Description of PLUG-19495.
The commit all operation in Panorama fails when a branch or hub firewall is added to an existing SD-WAN cluster.
This issue is addressed in SD-WAN plugin 3.2.3-h2, 3.2.4, 3.3.3, and 3.4.0.

PLUG-19159

Description of PLUG-19159.
After installing SD-WAN plugin 2.2.7 version, the SD-WAN Devices page (PanoramaSD-WANDevices) does not load intermittently.
This issue is addressed in SD-WAN plugin 2.2.7-h5 , 3.2.4, and 3.4.0.

PLUG-18888

Description of PLUG-18888.
(SD-WAN Mesh topology only) BGP connectivity cannot be established between the SD-WAN branch and hub firewalls.
This issue is addressed in SD-WAN plugin 3.4.0.

PLUG-18873

Description of PLUG-18873.
In Panorama, when you configure User-ID in the zone and push the configuration to the hub firewall, the configuration does not get enabled in the firewall.
This issue is addressed in SD-WAN plugin 3.2.3 , 3.2.4, and 3.4.0.

PLUG-18380

Description of PLUG-18380.
(SD-WAN hub-and-spoke deployments only) DDNS validation fails on Panorama (throwing a commit error) when one or more SD-WAN branches are configured with dynamic IP addresses and hub configured with static IP address.
This issue is addressed in SD-WAN plugin 3.3.3 and 3.4.0.

PLUG-17571

Description of PLUG-17571.
In an SD-WAN cluster, when the hub and branch firewalls (connecting to that hub) does not have a matching private link types, the plugin won't be able to generate the zone information. The SD-WAN plugin displays a warning message when no zone is associated with an interface.
This issue is addressed in SD-WAN plugin 3.2.4 and 3.4.0.