Configure Controller Port

Configure the controller port to communicate with the Prisma SD-WAN controller.
The Prisma SD-WAN ION 9000 uses the controller port to communicate with Prisma SD-WAN controller. By default, the controller port is configured for DHCP. However, if you want to set a static IP or if there are no DHCP-enabled networks, access the console and set a static IP on Controller 1.
Connect the controller 1 port to a copper 1G ethernet port, similar to how client PC or Laptops are connected to a corporate network. Ensure that you allow outbound internet access on port 443 to enable communication between the controller port and the Prisma SD-WAN controller service.
After this, the port is connected and the ION 9000 powered on, the ION 9000 automatically connects and registers with the Prisma SD-WAN controller. After the registration, the ION 9000 is available for claiming and configuration in the Prisma SD-WAN console.