Place in Network | Large and remote office data center. |
I/O |
Controller ports | 2 x 10/100/1000 RJ-45 |
WAN/LAN/Internet ports | - 8 x 10 gigabit Ethernet SFP+
- Ports 9 -12 support 10G SFP+ only, Ports 13 -16 support 1G SFP
and 10G SFP+
- 8x10 x 10/100/1000 RJ45
- Port pairs 1/2, 3/4, 5/6, and 7/8 have programmable inline fail-to-wire
capability for use in branch device mode
|
Power and Mechanical |
Type/Watts | 1+1 Hot swappable redundant PSUs 450W AC |
Power input | AC 100-240V @50-60Hz 6-3A |
Fan cooling | 4 x Hot Swappable cooling fans, direction of
air-flow is from front to rear. |
Certifications |
Certifications | IEC60950-1, cULus, FCC & CE Class A |
Environmental |
Operating temperature | 32°F to 104°F (0°C to 40°C) |
Storage temperature | -40°F to 158°F (-40°C to 70°C) |
Operating humidity | 5% to 90% (non-condensing) |
Storage humidity | 5% to 95% (non-condensing) |
Physical | |
1RU standard 4-post rack space | Recommended |
Weight | 21.38lbs |
Dimensions (D x W x H) | 19.69" X 17.24" X 1.73" |
Physical network connectivity | A single gigabit ethernet copper port with
DHCP, and two or more gigabit or ten gigabit ports for other features. |
BGP peers | Layer 2 connectivity to two separate network
devices that are currently participating in any dynamic routing protocol
(BGP, OSPF, EIGRP) with each other. |
Internet connectivity | Used to reach the Prisma controller. This connectivity can
be in the form of a private connection via a MPLS network through
a corporate data center. It can also be a public internet connection
provided via local a broadband connection. |