: PA-5200 Series Firewall Compliance Statements
Focus
Focus

PA-5200 Series Firewall Compliance Statements

Table of Contents

PA-5200 Series Firewall Compliance Statements

View the PA-5200 Series compliance statements.
The following lists the PA-5200 Series firewall hardware compliance statements:
  • VCCI
    This section provides the compliance statement for the Voluntary Control Council for Interference by Information Technology Equipment (VCCI), which governs radio frequency emissions in Japan.
    The following information is in accordance to VCCI Class A requirements:
    Translation: This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take corrective actions.
  • NEBS Requirements
    The following lists the Network Equipment Building System (NEBS) requirements for PA-5200 Series firewalls.
    • The firewall is intended to be installed in a Network Telecommunication Facility (Central Office) as part of a Common Bonding Network (CBN) or Isolated Bonding Network (IBN). Bare conductors must be coated with an appropriate antioxidant compound before crimp connections are made. All unplated connectors, braided strap, and bus bars must be brought to a bright finish and then coated with an antioxidant before they are connected.
      Fastening hardware must be compatible with the materials being joined and must preclude loosening, deterioration, and electrochemical corrosion of the hardware and the joined materials.
    • The firewall is suitable for connection to the Central Office or Customer Premise Equipment (CPE).
    • The DC battery return wiring on the firewall must be connected as an isolated DC return (DC-I).
      The intra-building ports (RJ-45 Ethernet ports, AUX ports, HA ports, and the MGT port) of the equipment or subassembly are suitable for connection to only intra-building or unexposed wiring or cabling. The intrabuilding port(s) of the equipment or subassembly must not be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and require isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient protection to connect these interfaces metallically to OSP wiring.The firewall must be connected to an external Special Protection Device (SPD) when installed and connected to commercial AC power.
      The firewall must be connected to an external Special Protection Device (SPD) when installed and connected to commercial AC power.
  • BSMI EMC Statement
    User warning: This is a Class A product. When used in a residential environment it may cause radio interference. In this case, the user will be required to take adequate measures.
    • Manufacturer—Flextronics International.
    • Country of Origin—Made in the USA with parts of domestic and foreign origin.
  • CE (European Union (EU) Electromagnetic Compatibility Directive)
    This device is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive (2014/30/EU).
    The above product conforms with Low Voltage Directive 2014/35/EU and complies with the requirements relating to electrical equipment designed for use within certain voltage limits.

Recommended For You