PAN-OS 10.2.18-h5 Addressed Issues
Table of Contents
Expand All
|
Collapse All
Next-Generation Firewall Docs
-
-
-
-
-
-
-
- PAN-OS 12.1
- PAN-OS 11.2
- PAN-OS 11.1
- PAN-OS 11.0 (EoL)
- PAN-OS 10.2
- PAN-OS 10.1
- PAN-OS 10.0 (EoL)
- PAN-OS 9.1 (EoL)
- PAN-OS 9.0 (EoL)
- PAN-OS 8.1 (EoL)
-
- PAN-OS 12.1
- PAN-OS 11.2
- PAN-OS 11.1
- PAN-OS 10.2
- PAN-OS 10.1
PAN-OS 10.2.18-h5 Addressed Issues
PAN-OSĀ® 10.2.18-h5 addressed issues.
Issue ID | Description |
|---|---|
|
PAN-316911
|
(VM-Series firewalls on Amazon Web Services (AWS) environments
only) Fixed an issue where a newly bootstrapped firewall
required a management server restart, relicensing, or license push
from Panorama to invoke the device certificate.
|
|
PAN-312706
|
Fixed an issue where the firewalls restarted due to a function
lacking a NULL-pointer sanity check.
|
|
PAN-308507
|
(Panorama managed firewalls only) Fixed an issue where the
firewall intermittently failed to maintain active log forwarding
streams to Strata Logging Service (SLS) even when duplicate logging
and enhanced application logging were enabled.
|
|
PAN-307795
|
Fixed an issue where Panorama incorrectly generated system logs
indicating a lost connection to its peer after an upgrade even when
High Availability was not configured.
|
|
PAN-307597
|
Fixed an issue where BGP peering sessions between a hub firewall and
a satellite firewall over GlobalProtect LSVPN failed to connect.
|
|
PAN-305415
|
Fixed an issue where commits caused high dataplane CPU utilization
and briefly increased Packet Descriptors, which disrupted
traffic.
|
|
PAN-304756
|
Fixed an issue on Panorama where, after you disabled the shared
optimization feature, a full configuration push to multi-vsys
devices caused a validation error.
|
|
PAN-303051
|
Fixed an issue on Panorama where a memory leak occurred related to
the reportd process due to retaining memory that was
temporarily used for report generation instead of releasing the
memory for reuse, which resulted in continuous accumulation and
memory exhaustion.
|
|
PAN-301409
|
Fixed an issue where Panorama failed to perform a selective push to a
managed device when device tags were added or modified on the policy
rules. The selective push would fail with the error message
Failed to generate selective push configuration.
Schema validation failed. Please try a full
push.
|
|
PAN-300671
|
Fixed an issue where traffic reports that were generated with
destination/source and destination/source hostnames were not
displayed in IPv4 format.
|
|
PAN-297610
|
Fixed an issue where the firewall became unresponsive after an
upgrade due to the fsck command scanning drive
partitions in parallel with the root partition, which caused the
process to take an extended amount of time.
|
|
PAN-295470
|
Fixed an issue on the firewall where the useridd process
continuously increased its memory consumption, which resulted in an
OOM condition that caused the firewall to restart.
|
|
PAN-291067
|
Fixed an issue where the devsrvr process periodically
exceeded its virtual memory limit and restarted, which led to
intermittent outages.
|
|
PAN-291009
|
Fixed an issue where, after a web server returned a 401 or 403 error,
the firewall was unable to decrypt HTTP/2 traffic, and the firewall
rejected all subsequent streams from the client.
|
|
PAN-289249
|
Fixed an issue where a memory leak occurred on the
reportd process when a WildFire update was
initiated while device telemetry data collection was in progress.
This resulted in an OOM condition.
|
|
PAN-284067
|
Fixed a cumulative memory leak in the devsrvr process
that occurred whenever the CLI command show running
application statistics was issued. This memory
leak would gradually consume system memory and produce an OOM
condition, causing the firewall to reboot.
|
|
PAN-280196
|
Fixed an issue in Prisma Access environments where the firewall
matched a HIP object but not on the HIP profile that contained the
object.
|
|
PAN-279364
|
(VM-Series firewalls with multiple NICs only) Fixed an issue
were the queue count in the task dump displayed an incorrect number
of queues for SR-IOV interfaces due to the queue mapping logic
incorrectly using a non-multi-NIC function.
|
|
PAN-274742
|
(VM-Series firewalls only) Fixed an issue where the
task-queue dump CLI command
returned incorrect information in multi-nic mode.
|
|
PAN-261825
|
Fixed an issue where traffic was dropped when Data Loss Prevention or
Advanced URL Filtering were enabled. This occurred when the payload
size was greater than 3.5 KB.
|
|
PAN-252809
|
Fixed an issue where a single PIM neighbor was sending 0.0.0.0 as its
address, which occurred because an improvement in PIM neighbor
address selection did not correctly account for configurations with
a single IP address.
|
|
PAN-242952
|
Fixed an issue where high SSL traffic depleted flex memory, which
prevented the firewall from revalidating SSLVPN client CAs during
configuration pushes.
|
|
PAN-230748
|
Fixed an issue where the firewall displayed the current time as the
expiration date for an imported certificate in the CLI output
instead of the correct expiry time due to an improper use of an
OpenSSL library function.
|
|
PAN-202911
|
Fixed an issue where a satellite tunnel was not established after
turning on satellite firewalls.
|