PAN-OS 10.2.7 addressed issues.
Issue ID
Description
PAN-236605
Fixed an issue where the configd process stopped responding due to a deadlock related to rule-hit-count.
PAN-232800
Fixed an issue where critical disk usage for
/opt/pancfg
increased continuously and the system logs displayed the following message:
Disk usage for /opt/pancfg exceeds limit, <value> percent in use
.
PAN-232132
Fixed an issue where DNS response packets were malformed when an Anti-Spyware Security Profile was enabled.
PAN-232059
Fixed an issue with memory management when processing large certificates using TLSv1.3.
PAN-231043
Fixed an issue where websites were not able to be opened via GlobalProtect with SSL-VPN when software cut through was enabled.
PAN-229691
Fixed an issue on Panorama where configuration lock timeout errors were observed during normal operational commands by increasing thread stack size on Panorama.
PAN-228998
Fixed an issue where multiple license status checks caused an internal process to stop responding.
PAN-228877
(
PA-7050 firewalls only
) Fixed an issue with OOM conditions that caused slot restarts due to
pan_cmd
consuming more than 300 MB.
PAN-227539
Fixed an issue where excess WIF process memory use caused processes to restart due to OOM conditions.
PAN-227368
Fixed an issue where the GlobalProtect app was unable to connect to a portal or gateway and GlobalProtect Clientless VPN users were unable to access applications if authentication took more than 20 seconds.
PAN-225337
Fixed an issue on Panorama related to Shared configuration objects where configuration pushes to multi-vsys firewalls when authentication took longer than 20 seconds.
PAN-224145
Fixed an issue in multi-vsys environments where, when Panorama was on a PAN-OS 10.2 release and the firewall was on a PAN-OS 10.1 release, commits failed on the firewall when inbound inspection mode was configured in the decryption policy rule.
PAN-223488
(
M-600 Appliances only
) Fixed an issue where closed ElasticSearch shards were not deleted, which resulted in shard purging not working as expected.
PAN-221190
(
PA-800 Series firewalls only
) Fixed an issue where the firewall rebooted due to I2C errors when unsupported optics were inserted in ports 5-8.
PAN-221126
Fixed an issue where Email server profiles (
Device > Server Profiles > Email and Panorama > Server Profiles > Email
) to forward logs as email notifications were not forwarded in a readable format.
PAN-221015
(
M-600 Appliances only
) Fixed an issue where ElasticSearch processes did not restart when the appliance was rebooted, which caused the Managed Collector ES health status to be downgraded.
PAN-218521
(
M-600 Appliances in Log Collector mode only
) Fixed an issue where Panorama continuously rebooted and became unresponsive, which consumed excessive logging disk space and prevented new log ingestion.
PAN-215268
Fixed an issue where selective push did not work for firewalls on PAN-OS 9.1 or an earlier release.
PAN-212761
Fixed an issue where the all_pktproc process stopped responding, which caused the dataplane to go down and caused HA failover.
PAN-193004
Fixed an issue where
/opt/pancfg
partition utilization reached 100%, which caused access to the Panorama web interface to fail.