: Alert Codes
Focus
Focus
Table of Contents

Alert Codes

This section lists alert codes for Prisma Access Insights.

About Alert Codes

Alert CodeAlert SpecificsSeverity
AL_MU_GATEWAY _SCHEDULED_AUTOSCALE_ FAILURE
Scheduled autoscale failure for Mobile User (MU) gateway.
Notification
AL_MU_IP_POOL_ USAGE
MU private IP pool use exceeds 85% worldwide or for the indicated theater.
IP subnet usage is compared to the total of IP subnets at the theater/worldwide level.
Usage exceeds 85%: Medium severity
AL_MU_IP_POOL_ CAPACITY
MU private IP pool use is 100% worldwide or for the indicated theater.
IP subnet usage is compared to the total of IP subnets at the theater/worldwide level.
Usage is 100%: High severity
AL_PRISMA_ACCESS_ INFRASTRUCTURE_ NOTIFICATION
Infrastructure notification related to Prisma Access upgrade, maintenance, or vulnerability.
Notification
AL_RN_ECMP_TUNNEL _DOWN
The ECMP tunnel {tunnel_name} for the remote network is down.
An alert is raised if in 10 minutes, the ECMP tunnel for the remote network is not detected to be up.
High
AL_RN_ECMP_TUNNEL_FLAP
The ECMP tunnel {tunnel_name} for the remote network is flapping.
An alert is raised if the ECMP tunnel for remote network flaps (up to down or down to up) 5 times within the past 10 minutes.
Medium
AL_RN_PRIMARY_WAN_ TUNNEL_DOWN
The primary WAN tunnel {tunnel_name} for the remote network is down.
An alert raised if in 10 minutes, the primary WAN tunnel for the remote network is not detected to be up.
High
AL_RN_PRIMARY_WAN_ TUNNEL_FLAP
The primary WAN tunnel {tunnel_name} for the remote network is flapping.
An alert is raised if the primary WAN tunnel for the remote network flaps (up to down or down to up) 5 times within the past 10 minutes.
Medium
AL_RN_SECONDARY_WAN _TUNNEL_DOWN
The secondary WAN tunnel {tunnel_name} for the remote network is down.
An alert is raised if in 10 minutes, the secondary WAN tunnel for the remote network is not detected to be up.
Low
AL_RN_SECONDARY_WAN_ TUNNEL_FLAP
The secondary WAN tunnel {tunnel_name} for the remote network is flapping.
An alert is raised if the secondary WAN tunnel for the remote network flaps (up to down or down to up) 5 times within the past 10 minutes.
Medium
AL_RN_SITE_DOWN
All tunnels for a remote network site are down.
An alert is raised if in 10 minutes, no tunnels for the remote network site in the location are detected to be up.
High
AL_RN_SITE_LONG_DURATION _EXCEEDED_CAPACITY
Remote Network bandwidth consumption was consistently greater than 100% of the capacity for at least one hour per day for at least three of the last five days.
This bandwidth alert applies to the per Remote Network site bandwidth allocation model and not to the Aggregate Bandwidth allocation model.
High
AL_RN_SITE_LONG_ DURATION_CAPACITY_ EXCEEDED_THRESHOLD
Remote Network bandwidth consumption was consistently greater than 90%, but less than 100%, of capacity for at least four hours per day for at least three of the last five days.
This bandwidth alert applies to the per Remote Network site bandwidth allocation model and not to the Aggregate Bandwidth allocation model.
Medium
AL_SC_ECMP_TUNNEL _DOWN
The ECMP tunnel {tunnel_name} for the service connection is down.
An alert is raised if in 10 minutes, the ECMP tunnel for the service connection is not detected to be up.
High
AL_SC_ECMP_TUNNEL_FLAP
The ECMP tunnel {tunnel_name} for the service connection is flapping.
An alert is raised if the ECMP tunnel for service connection flaps (up to down or down to up) 5 times within the past 10 minutes.
Medium
AL_SC_PRIMARY_WAN_ TUNNEL_DOWN
The primary WAN tunnel {tunnel_name} for the service connection is down.
An alert is raised if in 10 minutes, the primary WAN tunnel for the service connection is not detected to be up.
High
AL_SC_PRIMARY_WAN_ TUNNEL_FLAP
The primary WAN tunnel {tunnel_name} for the service connection is flapping.
An alert is raised if the primary WAN tunnel for the service connection flaps (up to down or down to up) 5 times within the past 10 minutes.
Medium
AL_SC_SECONDARY_WAN_ TUNNEL_DOWN
The secondary WAN tunnel {tunnel_name} for the service connection is down.
An alert is raised if in 10 minutes, the secondary WAN tunnel for the service connection is not detected to be up.
Low
AL_SC_SECONDARY_WAN _TUNNEL_FLAP
The secondary WAN tunnel {tunnel_name} for the service connection is flapping.
An alert is raised if the secondary WAN tunnel for the service connection flaps (up to down or down to up) 5 times within the past 10 minutes.
Medium
AL_SC_SITE_DOWN
All tunnels for a service connection site are down.
An alert is raised if in 10 minutes, no tunnels for the service connection site in the location are detected to be up.
High
AL_SC_SITE_LONG_DURATION _EXCEEDED_CAPACITY
Service connection bandwidth consumption was consistently greater than 100% of the capacity for at least one hour per day for at least three of the last five days.
High
AL_SC_SITE_LONG_DURATION _CAPACITY_EXCEEDED_ THRESHOLD
Service Connection bandwidth consumption was consistently greater than 90%, but less than 100%, of capacity for at least four hours per day for at least three of the last five days.
Medium