Issue ID
Description
CGSDW-3521
Resolved an issue where FC process was restarting
due to metadata buffer size.
CGSDW-3741
Resolved an issue where invalid response codes
(for example 302 or 404) for http probes were interpreted as valid
by the ION device.
CGSDW-4410
Resolved an issue when the ION device received an
application definition update which improperly removed the mapping
entries for the HTTP and SSL applications. The result of which could be,
incorrect policy matches for generic HTTP and SSL traffic.
Workaround: A one time reboot of the device or a restart of the app-engine process using the command debug process restart name=tcpproxy.
CGSDW-5020
Resolved an issue where a prefix was advertising
from both the Hub devices as the VPNs were in active/true status
on both the Hubs when the VPN keepalive timers were set with a high
value.
CGSDW-5416
Resolved an issue where after tunnel and BGP
creation by the Prisma Access CloudBlade, BGP was down and did not
show any status on the portal and CLI.
CGSDW-5605
Resolved an issue where ION 7000 device was
experiencing a slow memory leak.