: Known Issues in Prisma SD-WAN ION Device Release 6.3.1
Focus
Focus

Known Issues in Prisma SD-WAN ION Device Release 6.3.1

Table of Contents

Known Issues in
Prisma SD-WAN
ION Device Release 6.3.1

Learn about the Known Issues in
Prisma SD-WAN
ION device release 6.3.1.
The following table lists the known issues in
Prisma SD-WAN
ION Device Release 6.3.1.
Issue ID
Description
CGSDW-16922
Potential
fp-rte
crashes during the upgrade process may lead to longer upgrade durations. However, it does not impact systems that are already up and running.
CGSDW-20649
The SNMP daemon process is slowly consuming the memory in the ION device suggesting a possible memory leak.
CGSDW-20671
Incidents related to RADIUS server are raised even when a RADIUS server is not configured.
CGSDW-20864
If the only prefix of a VRF at a branch site is deleted, then the entries leaked to the DC site for the specific VRF are also deleted. The workaround is to configure at least one dummy global prefix for the VRF at the branch site.
CGSDW-21451
After being assigned to a site, the ION device does not receive the VRF context in time. This causes incorrect mapping between interfaces and VRFs.