Addressed Issues in Prisma SD-WAN ION Device Release 5.5.7
Focus
Focus

Addressed Issues in Prisma SD-WAN ION Device Release 5.5.7

Table of Contents

Addressed Issues in Prisma SD-WAN ION Device Release 5.5.7

Learn about the addressed issues in Release 5.5.7.
The following table lists the issues addressed in Prisma SD-WAN ION Device Release 5.5.7.
Issue IDDescription
CGSDW-3521Resolved an issue where FC process was restarting due to metadata buffer size.
CGSDW-3741Resolved an issue where invalid response codes (for example 302 or 404) for http probes were interpreted as valid by the ION device.
CGSDW-4410Resolved an issue when the ION device received an application definition update which improperly removed the mapping entries for the HTTP and SSL applications. The result of which could be, incorrect policy matches for generic HTTP and SSL traffic.


Workaround: A one time reboot of the device or a restart of the app-engine process using the command debug process restart name=tcpproxy.

CGSDW-5020Resolved an issue where a prefix was advertising from both the Hub devices as the VPNs were in active/true status on both the Hubs when the VPN keepalive timers were set with a high value.
CGSDW-5416Resolved an issue where after tunnel and BGP creation by the Prisma Access CloudBlade, BGP was down and did not show any status on the portal and CLI.
CGSDW-5605Resolved an issue where ION 7000 device was experiencing a slow memory leak.