Home
EN
Location
Documentation Home
Palo Alto Networks
Support
Live Community
Knowledge Base
Clear
Prisma SD-WAN ION Device Release Notes
:
Known Issues in Prisma SD-WAN ION Device Release 6.1.5
Updated on
Oct 22, 2024
Focus
Download PDF
Updated on
Oct 22, 2024
Focus
Home
Prisma
Prisma SD-WAN
Prisma SD-WAN ION Device Release Notes
Prisma SD-WAN ION Device Release 6.1
Known Issues in Prisma SD-WAN ION Release 6.1
Known Issues in Prisma SD-WAN ION Device Release 6.1.5
Download PDF
Prisma SD-WAN ION Device Release Notes
Known Issues in Prisma SD-WAN ION Device Release 6.1.5
Table of Contents
Filter
Version
6.1
6.1
Expand all
|
Collapse all
Prisma SD-WAN ION Device Release 6.1
Features Introduced in Prisma SD-WAN ION Release 6.1
Features Introduced in Prisma SD-WAN Release 6.1.3
Features Introduced in Prisma SD-WAN Release 6.1.1
Upgrade or Downgrade Considerations in Prisma SD-WAN ION Release 6.1
Upgrade or Downgrade Considerations in Prisma SD-WAN ION Device Release 6.1.1
CLI Commands in Prisma SD-WAN ION Release 6.1
CLI Commands in Prisma SD-WAN ION Device Release 6.1.2
CLI Commands in Prisma SD-WAN ION Device Release 6.1.1
Addressed Issues in Prisma SD-WAN ION Release 6.1
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.10
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.9
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.8
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.7
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.6
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.5
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.4
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.3
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.2
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.1
Known Issues in Prisma SD-WAN ION Release 6.1
Known Issues in Prisma SD-WAN ION Device Release 6.1.10
Known Issues in Prisma SD-WAN ION Device Release 6.1.9
Known Issues in Prisma SD-WAN ION Device Release 6.1.8
Known Issues in Prisma SD-WAN ION Device Release 6.1.7
Known Issues in Prisma SD-WAN ION Device Release 6.1.6
Known Issues in Prisma SD-WAN ION Device Release 6.1.5
Known Issues in Prisma SD-WAN ION Device Release 6.1.4
Known Issues in Prisma SD-WAN ION Device Release 6.1.3
Known Issues in Prisma SD-WAN ION Device Release 6.1.2
Known Issues in Prisma SD-WAN ION Device Release 6.1.1
Known Issues in
Prisma SD-WAN
ION Device Release 6.1.5
Learn about the known issues in
Prisma SD-WAN
ION Release 6.1.5.
The following list includes outstanding known issues specific to Prisma SD-WAN ION release 6.1.5.
Issue ID
Description
CGSDW-13397
This issue is now resolved in ION device software version 6.1.6. See
Addressed Issues in Prisma SD-WAN ION Device Release 6.1.6
.
Core files seen during TCP SYN scan which is using up memory and causing FC to crash.
CGSDW-14432
The
fp-rte
process crashes when fetching information on security policy counters and app stats.
CGSDW-15967
High memory consumption by the ADEM process causes ION device reboot.
Previous
Known Issues in Prisma SD-WAN ION Device Release 6.1.6
Next
Known Issues in Prisma SD-WAN ION Device Release 6.1.4