Environmental Specifications

Learn about the temperature range, airflow, noise, and other environmental specifications of PA-400 Series firewalls.
The following table describes PA-400 Series firewall environmental specifications.
Specification
Value
Operating temperature range
PA-410, PA-440, PA-450, PA-455,
PA-455-5G,
and PA-460
  • 32°F to 104°F (0° to 40°C)
PA-415,
PA-415-5G,
and PA-445
  • 32°F to 113°F (0° to 45°C)
Non-operating temperature
  • -4°F to 158°F (-20° to 70°C)
Humidity tolerance
10% to 90% non-condensing
Airflow
The PA-455-5G is the only PA-400 Series firewall that features a single dual-rotor fan that can be replaced.
The other PA-400 Series firewalls use passive cooling and do not contain fans.
Maximum BTUs/hour
PA-410
—82/hour
PA-415 and PA-415-5G
—461/hour
PA-440
—102/hour
PA-445
—460/hour
PA-450 and PA-460
—123/hour
PA-455
—502/hour
PA-455-5G
—215/hour
Electromagnetic Interference (EMI)
FCC Class B, CE Class B, VCCI Class B
Acoustic noise
Emits no sound.
Maximum operating altitude
10,000ft (3,048m)