Learn how to connect AC power to the PA-1500 Series Firewall.
The following procedure describes how to connect AC power to a PA-1500 Series firewall with AC power supplies.
Learn how to Set Up a Connection to the Firewall based on your desired boot mode prior to powering on the firewall for the first time.
To avoid injury to yourself or damage to your Palo Alto Networks® hardware or the data that resides on the hardware, read the Product Safety Warnings.
  1. Ensure that your power source(s) are powered off.
  2. Remove the nut and star washer from the ground stud on the back of the firewall.
  3. Crimp a 14AWG ground cable to a ring lug (cable and lug not included) and then attach the ring lug to the ground stud on the firewall. Replace the star washer and nut, then connect the other end of the cable to earth ground.
  4. Connect the AC power cord to the input on the PSU.
    Before powering on the firewall, ensure that you have connected your Ethernet cables in accordance to the mode you wish to boot the firewall in (standard mode or Zero Touch Provisioning mode) as specified in Set Up a Connection to the Firewall.
  5. (PA-1530-POE only) Repeat the previous step for the second power supply.