New Feature/Enhancement | Description |
---|---|
Improved IoT visibility across SASE |
Improved IoT visibility across Prisma SASE with Prisma SD-WAN exporting logs to the IoT Security portal.
Device Software Version Required: 6.2.1 and later
|
Support for User-ID based policies | Support for User-ID based policies
provides ease of configuration and consistency, as the same policy can
be enforced for the same user or group, irrespective of the IP address.
Device Software Version Required: 6.2.1 and
later |
ION 9200 Field Replaceable Unit (FRU) Storage drives (SSD) Switchover event |
In the event of failure of an ION 9200 FRU
SSD, logging and storage of core files will be switched
to on-board SSD, till a replacement FRU SSD is added.
Device Software Version Required: 6.2.1 and later
|
Support for enhanced high availability topologies |
Device Software Version Required: 6.2.1 and later
|
Scale improvements for multicast |
A data center site can now support a maximum of 400 branch sites for
multicast traffic. For a
specific multicast group, a data center site can support a maximum
of 400 branch sites subscribing to that multicast group.
Device Software Version Required: 6.2.1 and later
|
IPv6 with LAN |
Prisma SD-WAN now supports IPv6 on LAN interfaces
which have L3 LAN Forwarding enabled for branch and data center
devices. IPv6 is now supported for statistics, address distribution,
DHCP, DNS, ZBFW, QoS, policy support, flow control, and application
identification.
For default path
policy, only Direct on Any Private or Prisma SD-WAN on Any Public or Private paths are
supported in Active Path.
Device Software Version Required: 6.2.1 and later
|
Support for device uptime and thermal sensor data and alarm |
Enhancements are made to monitor the device operating
temperatures:
Device Software Version Required: 6.2.1 and later
|
Cellular Certifications | New cellular certifications by Verizon, Telstra, Bell,
and Australian country certification are supported for ION 1200 Cellular
devices. For more information, refer to the ION 1200 Hardware Reference.
Device Software Version Required: 6.2.1 and
later |
Aggregate Bandwidth utilization report
| Prisma SD-WAN supports aggregate on-demand bandwidth utilization reports showing the monthly site and tenant utilization to help understand the bandwidth consumption. |