Install a PA-545-POE or PA-555-POE firewall in an equipment rack using the
PAN-1RU-4POST-RACK-12 mounting kit.
- Secure the power adapter(s) to the mounting tray.
- For each power adapter being installed (for a maximum of two), install
two stoppers into the designated locations on the mounting tray. Use two
#6-32 screws to secure each stopper from the underside of the mounting
tray.
- Place each power adapter into the location between the two installed
stoppers.
350W Power Adapter
530W Power Adapter
Route the power cables through paths on the mounting tray.- Using the following images as references, guide the remaining length of
the power cables along the mounting tray. Thread the provided cable ties
through the lances and cutouts in the mounting tray. Wrap the cable ties
around the power cables, ensuring that the power cables are fixed in
place.350W Power Adapter
530W Power Adapter
Install retention clamps over the power cord that plugs into your power source.- Connect the power cords into the power adapter.
- Thread each power cord through a retention clamp, then snap the
retention clamp to the mounting tray.
- Tighten the retention clamp so that the power cord is locked in
place.
Install the firewall in the mounting tray.- Align the four rubber feet of the device to the mounting tray, then
secure it using four M3 x 6mm flathead screws.
Slide one of the adjustable mounting brackets into one of the fixed mounting brackets to create a mounting rail. Repeat for the second mounting rail. The adjustable and fixed brackets are the same for the left and right side.
Align the bottom edge of the mounting rails to the bottom of the space reserved for your firewall. Align the slotted holes in the adjustable mounting bracket to the holes on the rear of the equipment frame.Secure the rails to the equipment frame with mounting screws (not provided) compatible with your equipment frame. Tighten the screws to their recommended torque value.
Slide the mounting tray into the rails previously fixed to the equipment rack. Stop when the front flange on the mounting tray is flush with the front of the rail.Align the slotted hole in the mounting tray to the hole in the equipment frame. Secure the mounting tray to the equipment frame on both sides using one screw each (not provided). The screws must be compatible with your equipment frame.
Proceed to Connect Power to the PA-500 Series Firewall. - For each power adapter being installed (for a maximum of two), install