: Replace a System Drive in a PA-5450 MPC
Focus
Focus

Replace a System Drive in a PA-5450 MPC

Table of Contents

Replace a System Drive in a PA-5450 MPC

Learn how to replace an SSD in the PA-5400 Series firewall.
  1. Identify the failed drive and determine the drive model using the show system raid detail CLI command.
    When the system drives are functioning normally, all system drive partitions show both drives with the status clean. If a system drive fails, the Overall System Drives RAID status shows degraded, one or more failed partition array shows clean, degraded, and one of the drives will be missing (Sys1 or Sys2).In this example, the output from the show system raid detail command shows that the drive model is MICRON_M510DC_MT, the panlogs partition shows the status clean, degraded, and drive Sys1 is missing from the panlogs array; together, these indicate that you need to replace the Sys1 drive.
    admin@PA-5450> show system raid detail
    
    Overall System Drives RAID status           degraded
    -----------------------------------------------------------------------------
    Drive status
       Disk id Sys1                             Present     (MICRON_M510DC_MT)
       Disk id Sys2                             Present     (MICRON_M510DC_MT)
    -----------------------------------------------------------------------------
    Partition status
    
    panlogs                                     clean, degraded
       Drive id Sys2                            active sync
    maint                                       clean
       Drive id Sys1                            active sync
       Drive id Sys2                            active sync
    sysroot0                                    clean
       Drive id Sys1                            active sync
       Drive id Sys2                            active sync
    sysroot1                                    clean
       Drive id Sys1                            active sync
       Drive id Sys2                            active sync
    pancfg                                      clean
       Drive id Sys1                            active sync
       Drive id Sys2                            active sync
    panrepo                                     clean
       Drive id Sys1                            active sync
       Drive id Sys2                            active sync
    swap                                        clean
       Drive id Sys1                            active sync
       Drive id Sys2                            active sync
  2. Remove the failed drive from the RAID 1 array. In this example, run the following command to remove drive Sys1 from the array:
    admin@PA-5450> request system raid remove sys1
  3. Confirm that the failed drive is removed from all partitions. In the following output of the show system raid detail, you see that drive id Sys1 is now missing from all partitions.
    admin@PA-5450> show system raid detail
    
    Overall System Drives RAID status              degraded
    -----------------------------------------------------------------------------
    Drive status
       Disk id Sys1                                Present  (MICRON_M510DC_MT)
       Disk id Sys2                                Present  (MICRON_M510DC_MT)
    -----------------------------------------------------------------------------
    Partition status
    
    panlogs                                        clean, degraded
       Drive id Sys2                               active sync
    maint                                          clean, degraded
       Drive id Sys2                               active sync
    sysroot0                                       clean, degraded
       Drive id Sys2                               active sync
    sysroot1                                       clean, degraded
       Drive id Sys2                               active sync
    pancfg                                         clean, degraded
       Drive id Sys2                               active sync
    panrepo                                        clean, degraded
       Drive id Sys2                               active sync
    swap                                           clean, degraded
       Drive id Sys2                               active sync
  4. Ensure that you have access to an ESD work surface for placement of the Management Processor Card (MPC).
  5. Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching your skin. Then attach (snap) one end of the ground cable to the wrist strap and remove the alligator clip from the banana clip on the other end of the ESD grounding cable. Plug the banana clip end into one of the ESD ports located on the back of the appliance before handling ESD sensitive hardware. For details on the ESD port location, see PA-5450 Back Panel.
  6. Remove the MPC from card slot 7 of the appliance. See Replace a PA-5400 Series Management Processor Card (MPC) for details on removing the MPC.
  7. Place the MPC on an ESD work surface. Detach your wrist strap’s ground cable from the ESD port on the appliance and securely attach the alligator clip to the new ESD surface.
  8. Flip the MPC over and locate the two SSDs on the bottom surface of the card. Remove the retention screw for the SSD you intend to replace.
    The plastic standoff becomes loose after the retention screw is removed. Do not lose the standoff as it is needed when installing the new SSD.
  9. Gently pull the SSD away from its mating connector. Place the old SSD to the side.
  10. Slide the new SSD into the vacant mating connector. Ensure that the SSD aligns with the plastic standoff on the MPC.
  11. Fasten the retention screw back into place at a torque of 4 in-lbs.
    Exceeding a torque of 4 in-lbs will damage the equipment.
  12. Before re-installing the MPC, plug the banana clip end of your ESD wrist strap into one of the ESD ports located on the back of the appliance.
  13. Slide the MPC back into slot 7. See Install a PA-5400 Series Firewall Management Processor Card (MPC) for more information.