The following table describes PA-50R Series firewall environmental specifications.
SpecificationValue
Operating temperature range
PA-52R-5G
-40°F to 140°F (-40°C to 60°C)
The PA-52R-5G can operate at up to 158°F (70°C) only if there is 240 LFM (linear feet per minute) of external airflow.
PA-54R-POE, PA-54R-POE-D-5G, PA-56R-POE-5G
-40°F to 158°F (-40°C to 70°C)
Humidity tolerance
10% to 90% non-condensing
Airflow
The PA-50R Series firewalls use passive cooling and do not contain fans.
Maximum BTUs/hour
PA-52R-5G—136.5 BTUs/hour
PA-54R-POE—767.7 BTUs/hour
PA-54R-POE-D-5G—767.7 BTUs/hour
PA-56R-POE-5G—767.7 BTUs/hour
Acoustic noise
Emits no sound.
Maximum operating altitude
10,000 ft (3048m)