: Syslog Server Support in Prisma SD-WAN
Focus
Focus

Syslog Server Support in Prisma SD-WAN

Table of Contents

Syslog Server Support in
Prisma SD-WAN

Prisma SD-WAN Syslog is a protocol through which network devices send event messages over User Datagram Protocol (UDP) /Transmission Control Protocol (TCP) to a Syslog server.
Prisma SD-WAN
ION devices provide Syslog support to log and export flow and event information to Syslog servers.
Syslog is a protocol through which network devices send event messages over User Datagram Protocol (UDP) /Transmission Control Protocol (TCP) to a Syslog server. As a wide range of devices support the protocol, you may use it to log different events. For example, device user session logins or access-denied events are some of the events you may send to a Syslog server.
A Syslog server can reside inside or outside of a branch or a data center or in the cloud. The maximum number of Syslog servers supported per ION device is 16. The ION devices use the Syslog protocol to:
  • Forward device events such as alerts and alarms to a remote Syslog server(s).
  • Forward device Authentication logs to a remote Syslog server(s).
  • Forward flow logs to a remote Syslog server(s).

Event Logs

Event logs are generated in response to alerts and alarms in the device. Below is a sample event log message sent to a Syslog server.
Feb 14 10:38:11 172.20.75.186 alert: CLOUDGENIX_HOST="ion7k-Hub" DEVICE_TIME="2018-02-14T10:36:49.000" STATUS="Not cleared" CODE="DEVICESW_GENERAL_PROCESSRESTART"SEVERITY="minor" PROCESS_NAME="event_forward" ELEMENT_ID="15174644824510129"Feb 14 10:38:11 172.20.75.186 alert: CLOUDGENIX_HOST="ion7k-Hub" DEVICE_TIME="2018-02-14T10:37:22.000" STATUS="Not cleared" CODE="DEVICESW_GENERAL_PROCESSRESTART"SEVERITY="minor" PROCESS_NAME="scm" ELEMENT_ID="15174644824510129"

Authentication Logs

Authentication logs are generated when a user is authenticated to login to the device. Below is a sample Auth log message sent to a Syslog server.
Feb 14 10:44:58 172.20.75.186 log: CLOUDGENIX_HOST="ion7k-Hub" DEVICE_TIME="2018-02-14T10:44:58.881Z" MSG="sshd-login keyboard-interactive/pam" SEVERITY="minor"PROCESS_NAME="sshd" FACILITY="auth" USER="elem-admin" ELEMENT_ID="15174644824510129"
While configuring Syslog export on the device, you can filter using severity levels for logs/events to export to the Syslog server. You may configure severity levels as critical, major, or minor. The default severity level is minor.
When you set a severity level for a device, logs and events for the selected severity level and higher are exported to the Syslog server. For example, if the chosen severity level is major, then all major and critical events and logs will be forwarded to the Syslog server.