Addressed Issues in Prisma SD-WAN ION Device Release 6.1.5
Focus
Focus

Addressed Issues in Prisma SD-WAN ION Device Release 6.1.5

Table of Contents

Addressed Issues in Prisma SD-WAN ION Device Release 6.1.5

Learn about the issues addressed in Prisma SD-WAN ION device release 6.1.5.
The following table lists the issues addressed in Prisma SD-WAN ION Device Release 6.1.5.
Issue IDDescription
CGSDW-3841Resolved an issue where a DC ION device was not advertising BGP prefixes learnt from the branch LAN peer to the core peer after an HA switchover.
CGSDW-8622Resolved an issue in which the rtr-manager process was constantly restarting.
CGSDW-11150Resolved an issue where there could be a possibility of malicious command injections through the ION device CLI.
CGSDW-11384Resolved an issue where static route polling was failing after 18 hours.
CGSDW-11581Increased the concurrent flow support of the ION-1200-S device to 40,000.
CGSDW-12698Resolved an issue where the branch ION device wasn't passing ICMP traffic originating from a DC ION device to a non-CGNX prefix from WAN to LAN.
CGSDW-13805Resolved an issue wherein received BGP routes were getting filtered in case of uneven route lengths.
CGSDW-14342Resolved an issue where branch to branch VPNs could not be created for the ION 1200-S device.
CGSDW-15027Resolved an issue where the SNMP interface bandwidth was being reported incorrectly after upgrading the device software version from 5.6.x.
CGSDW-15039Resolved an issue where the domain names were not displayed for Applications on the Flows tab.
CGSDW-15238Resolved an issue where the fp-metrics process was crashing on clearing flows on the ION device during traffic flow.
CGSDW-15257Resolved an issue wherein previously reachable prefixes from a DC ION device became unreachable after upgrading the device software to version 6.1.2.
CGSDW-15393Addressed an issue where the Advertised auto-negotiation mode duplex setting was erroneously set to Yes following a reboot of the ION device through the web interface.
CGSDW-15529Resolved an issue where the per BGP peer statistics table did not have any data.
CGSDW-15623Resolved an issue where the FC process was restarting on the ION device.
CGSDW-15663Resolved an issue where the thmgr process did not start after upgrading the device software version.
CGSDW-15828Resolved an issue where the alarm for Power Supply Unit (PSU) removal was not working for the ION 5200 and 9200 devices.
CGSDW-15868Resolved an issue wherein high memory consumption by the ADEM process was causing other processes to crash and device to reboot.
CGSDW-16003Resolved an issue where the FC was crashing due to the ADEM process.
CGSDW-16005Resolved an issue where the app-engine was crashing on an ION 2000 device during continuous traffic flow.
CGSDW-16269Resolved an issue where high payload traffic sent over Private WAN VPN with a high throughput was dropping.
CGSDW-16280Resolved an issue wherein the DC ION device did not forward traffic to the mgmt-vlan prefix if the management port of the core switch went down.
CGSDW-16717Resolved an issue where the fp-rte process was crashing if the packet size was larger than 16384.
CGSDW-16839Resolved an issue where the app-engine was consuming high memory during high traffic flows.
CGSDW-17138Fixed a BGP attribute that was seen as corrupted.
CGSDW-17418Resolved an issue where the ION 5200 and 9200 devices were unable to handle oversize packets.