: dump sensor type
Focus
Focus
Table of Contents

dump sensor type

Use the
dump sensor type
command to display the information from sensor logs. Information displayed includes the values for voltage sensors, eight core temperatures, board temperature sensors, temperature of line card i350CPU, and fan speeds.

Command

dump sensor type= (all | temperature | voltage | fan)
<start date= YYYY-MM-DD> <end date=YYYY-MM-DD >

Options

all
Enter all to display information for all sensors.
temperature
Enter temperature to display information for temperature sensors.
voltage
Enter voltage to display information for voltage sensors.
fan
Enter fan to display information for fans.

Command Notes

Role
Super, Read Only, Monitor
Related Commands
dump sensor type summarize
Introduced in
Release 5.1.3

Example

dump sensor type=all start=2023-03-14T00:00 end=2023-03-14T03:00 time 1v 5v vcore vddr core0 core1 core2 core3 sys (mV) (mV) (mV) (mV) (°C) (°C) (°C) (°C) (°C) 2023-03-14T00:04:28 1000 5056 984 1520 36 36 35 35 46 2023-03-14T00:19:28 1000 5056 984 1520 35 35 34 35 46 2023-03-14T00:34:28 1000 5056 984 1520 36 36 34 34 46 2023-03-14T00:49:28 1000 5056 984 1520 36 36 35 35 46 2023-03-14T01:04:28 1000 5056 984 1520 36 36 37 36 47 2023-03-14T01:19:28 1000 5056 984 1520 36 36 36 36 47 2023-03-14T01:34:28 1000 5056 984 1520 36 36 37 35 47 2023-03-14T02:04:28 1000 5056 984 1520 37 37 35 37 47 2023-03-14T02:19:28 1000 5056 984 1520 37 37 35 35 47 2023-03-14T02:49:28 1000 5056 984 1512 36 36 36 36 47

Recommended For You