PA-7000 100G NPC Requirements
Table of Contents
Expand all | Collapse all
-
-
-
- PA-7000 Series Power Configuration Options
- Determine PA-7000 Series Firewall Power Configuration Requirements
- Connect AC Power to a PA-7050 Firewall
- Connect DC Power to a PA-7050 Firewall
- Connect AC Power to a PA-7080 Firewall
- Connect DC Power to a PA-7080 Firewall
- View PA-7000 Series Firewall Power Statistics
- Connect Cables to a PA-7000 Series Firewall
- Install the PA-7080 Firewall EMI Filter
-
- Replace a PA-7000 Series Firewall Air Filter
- Replace a PA-7000 Series SMC Boot Drive
- Replace a PA-7000 Series Firewall LPC Drive
- Re-Index the LPC Drives
- Replace a PA-7050-SMC-B or PA-7080-SMC-B Drive
- Increase the PA-7000 Series Firewall LPC Log Storage Capacity
PA-7000 100G NPC Requirements
Learn about the PA-7000 100G NPC system and hardware
requirements.
The following information describes the system and hardware requirements
for the PA-7000 100G Network Processing Card (NPC).
If you install the Switch Management Card (SMC-B), Log Forwarding
Card (LFC), or PA-7000 100G NPC in a PA-7050 firewall, you must
install the second-generation fan trays (PA-7050-FANTRAY-L-A and PA-7050-FANTRAY-R-A).
If you install these cards in a PA-7080 firewall, you must install
the electromagnetic interference (EMI) filter. You do not have to
install these components if the last five digits of the firewall
serial number is 10,000 or greater because the PA-7050 will have
the second-generation fan trays installed and the PA-7080 will have
a built-in EMI filter.
- PAN-OS 9.0 or later.
- (PA-7050 only) Install the second-generation fan tray (PA-7050-FANTRAY-L-A and PA-7050-FANTRAY-R-A) to increase cooling capacity. The Replace a PA-7050 Fan Tray topic shows how to remove and install a fan tray.
- (PA-7080 only) Install the PA-7080 Firewall EMI Filter to reduce electromagnetic interference.