: PA-7080 Power Supply LEDs
Focus
Focus

PA-7080 Power Supply LEDs

Table of Contents

PA-7080 Power Supply LEDs

Use the following information to learn how to interpret the LEDs on the PA-7080 AC power supply.
LEDs
Description
  • Input
    —Green indicates that the power supply input is within normal limits, blinking indicates power input is out of normal limits, and off indicates no power input.
  • Output
    —Green indicates that the power supply DC output to the chassis components are within normal limits, blinking indicates power overload, and off indicates no DC output power.
  • Warning
    —Yellow indicates that the power supply temperature is exceeded, blinking indicates that the power supply needs service and should be replaced, and off indicates no warning.
  • Fault
    —Red indicates a power supply failure, blinking indicates that the management plane cannot communicate with the power supply, and off indicates no issues.
The following table describes the PA-7080 DC power supply LEDs.
LEDs
Description
  • Input
    —Green indicates that the power supply input is within normal limits and off indicates no power input.
  • Output
    —Green indicates that the power supply DC output to the chassis components are within normal limits and blinking indicates overload.
  • Warning
    —Yellow indicates that the power supply temperature is exceeded and off indicates no warning.
  • Fault
    —Red indicates a power supply failure and off indicates no issues.